Explore medium- and high-voltage switching duties, insulation, cable terminations and testing. Start with the switching-device overview, then compare equipment for your application.Switching devices · Breaker vs. contactor
-

Generator Circuit Breaker Breaking Capacity: Study Both Fault Sources
A medium-voltage generator circuit breaker (GCB) cannot be specified from one symmetrical short-circuit kA value. Study faults fed from the generator and faults fed from the power system…
-

Medium-Voltage Fuse Ratings Explained: Voltage, Current and Breaking Range
An MV fuse link has several different ratings, not one “size.” Rated voltage addresses the application voltage; rated current relates to carrying normal current under specified conditions; breaking-current…
-

Medium-Voltage Circuit Breaker Operating Sequence Explained
An operating sequence describes a breaker’s assigned ability to perform specified open and close–open operations at stated intervals; it is not an instruction to reclose every faulted feeder.…
-

Switching Devices in Medium-Voltage Switchgear
Medium-voltage switchgear uses different devices for different electrical duties. A circuit breaker can interrupt specified fault currents; a load switch interrupts specified normal or limited abnormal currents; a…
-

Current Chopping in Vacuum Circuit Breakers: Why It Causes Switching Overvoltage
Current chopping is the premature extinction of alternating current before its natural current zero. In a vacuum circuit breaker, a small inductive current may become unable to sustain…
-

MV Disconnectors and Earthing Switches: An IEC 62271-102 Selection Guide
Select a medium-voltage disconnector to establish the specified isolating condition after another device has interrupted the load. Select an earthing switch to connect an isolated circuit to earth…
-

Circuit Breaker vs. Contactor: Selecting for Medium-Voltage Switching Duty
Choose a medium-voltage circuit breaker when the switching device itself must interrupt rated short-circuit current and support broad feeder, transformer, bus or system-protection duties. Choose a contactor-based arrangement…
-

MV Cable Terminations: Stress Control, Creepage, and Why They Fail
For medium-voltage (MV) cable terminations, the first place to investigate is usually the transition between the shielded cable and the connected equipment—not the bulk cable insulation in isolation.…
-

SF6 vs Vacuum Circuit Breakers: How to Choose for 11–36 kV Switchgear
For most new 11–36 kV projects, a vacuum circuit breaker should be the starting point—not because vacuum is universally superior, but because it can meet many distribution duties…