Founder and author / OHELE
MAX
MAX is the founder and primary author of OHELE. A lifelong learner in the electrical industry, he studies how power systems, equipment, protection, and control work together—from the grid and substations to transformers, switchgear, motors, drives, and end-use installations.
His work focuses on turning technical principles, equipment documentation, standards, and fault mechanisms into clear explanations that help readers understand electrical technology, compare options, and investigate problems more systematically.
Contact MAX: [email protected]
Coverage
- Power systems
- High and low voltage
- Transformers
- Protection and control
- Motors and automation
- Renewables and storage
- Safety and standards
Selected work
Explore MAX’s guides to distribution-substation equipment and power flow, circuit-breaker feeder cable sizing, and vacuum circuit-breaker current chopping. These articles show the range of electrical topics covered in his published work.
Latest from MAX

Neutral Switching and Protection: Linked Poles, Isolation and Safe Boundaries
“Can a breaker or switch be installed in the neutral?” has no useful worldwide yes-or-no answer. A separate neutral pole operating with the line poles is different from…

Neutral Conductor Sizing: When a Reduced Neutral Is Not Justified
The neutral conductor is not inherently smaller than the phase conductors. In a balanced three-phase linear load, fundamental-frequency phase currents cancel at the neutral point. In an installation…

MV Transformer Feeder Cable Sizing: A 20/3.3 kV Calculation Workflow
An MV transformer feeder cannot be sized from transformer MVA and an ampacity table alone. First identify which winding the cable serves; then establish insulation duty, route-specific thermal…

Marine Terminal Blocks: Corrosion, Vibration and Connection Verification
A corrosion-resistant marine terminal block is not a complete corrosion-resistant connection. The contact system, conductor preparation, cable support, enclosure and operating environment must work together. Selection should start…

Substation Energy Metering: CT/VT Scaling and Commissioning Checks
Accept substation energy metering only after verifying the chain from primary conductors through instrument transformers and meter configuration to the reported energy register. Correct CT/VT ratios do not…

SPD Selection for TN, TT and IT Earthing Systems
Select a surge protective device from the earthing arrangement at its actual connection point, not from the supply voltage alone. Identify the available conductors, the voltage between each…

MCB Tripping Causes: A Safe Diagnostic Path Before Resetting
An MCB trip is a protection event, not permission to install a larger breaker. First identify which device operated, when it operated and what changed on the circuit.…

Ferroresonance in Transformers and VTs: Evidence, Diagnosis and Mitigation
Suspect ferroresonance when a switching event leaves a credible interaction between nonlinear magnetic excitation and system capacitance, particularly under a lightly loaded or unusual phase configuration. Confirm the…

86 Lockout Relay Design: Trip Matrix, Close Blocking and Reset Authority
An 86 lockout function retains a protection action until an authorized reset. Design it by specifying which causes latch it, which equipment it trips, which closing paths it…

Pluggable Terminal Blocks for LED Driver Maintenance: A Safe Interface Review
A matched pluggable terminal interface can make an LED driver easier to replace without repeatedly disturbing every field-wire termination. The benefit exists only when the connector, driver, LED…