Founder and author / OHELE
MAX
MAX is the founder and primary author of OHELE. A lifelong learner in the electrical industry, he studies how power systems, equipment, protection, and control work together—from the grid and substations to transformers, switchgear, motors, drives, and end-use installations.
His work focuses on turning technical principles, equipment documentation, standards, and fault mechanisms into clear explanations that help readers understand electrical technology, compare options, and investigate problems more systematically.
Contact MAX: [email protected]
Coverage
- Power systems
- High and low voltage
- Transformers
- Protection and control
- Motors and automation
- Renewables and storage
- Safety and standards
Selected work
Explore MAX’s guides to distribution-substation equipment and power flow, circuit-breaker feeder cable sizing, and vacuum circuit-breaker current chopping. These articles show the range of electrical topics covered in his published work.
Latest from MAX

How Overcurrent Protection Changes Arc-Flash Incident Energy
The protective device changes an arc-flash estimate primarily through the arcing current it sees and how long it takes to clear that current. A current-limiting fuse, instantaneous breaker,…

MCCB Selection for Automatic Power-Factor-Correction Panels
Select the incoming molded-case circuit breaker (MCCB) for an automatic power-factor-correction (APFC) panel from the bank’s maximum operating current, installation fault level, protection/coordination requirements and verified assembly design.…

Control Transformer Sizing for Contactor Pickup and Holding
Do not size a contactor control transformer from coil holding VA alone. Build at least two load cases: the largest credible simultaneous pickup demand, and the steady sealed/holding…

Low-Voltage Circuit Breaker Selection for Selective Coordination
Selectivity means a downstream fault is cleared by the protective device nearest that fault while an upstream device remains closed, within a defined range of fault currents. To…

GFCI vs. AFCI: What Each Device Protects Against
A ground-fault circuit interrupter (GFCI) and an arc-fault circuit interrupter (AFCI) respond to different hazards. A GFCI compares current leaving and returning on the intended circuit conductors and…

Substation Breaker Trip Troubleshooting: Reconstruct the Event Before Reclosing
When a substation circuit breaker trips unexpectedly, first establish what ordered it to open and whether it actually interrupted current. Do not treat every open breaker as a…

Switching Devices in Medium-Voltage Switchgear
Medium-voltage switchgear uses different devices for different electrical duties. A circuit breaker can interrupt specified fault currents; a load switch interrupts specified normal or limited abnormal currents; a…

How to Lower Terminal Block Assembly Cost Without Weakening Safety
The lowest-cost terminal-block build is not necessarily the one with the cheapest block. For a repeatable low-voltage panel, reduce total installed cost by controlling wire preparation, terminal selection,…

How to Read Terminal Block Markings in UL and IEC Panels
A marking on a terminal block is a starting point for verification, not permission to connect any wire that fits. Read the component identification, voltage and current ratings,…

EV Battery Busbar Design: Current, Heat, Insulation, and Validation
Size an EV battery busbar from the actual continuous and pulse-current duty using resistance at operating temperature, then validate joints, cooling, insulation coordination, fault forces, vibration, manufacturing tolerance…